Page 49 - TFC 2022 Catalogue
P. 49

Bronze Bodied Domestic Hot Water Pump


                                     Product Code BRZPUMP













































            Installations which have a long pipe run to the final hot water tap or shower may suffer from excessive draw-off (and therefore wastage) of
            water that has cooled in the pipe, before the required hot water is available. A secondary hot water circuit with circulating pump will
            overcome the problem, ensuring that no water is wasted, because hot water is immediately available even from the tap furthest from the
            storage point.
            A standard pump would fail prematurely in this application; the pump body is bronze so that it does not react with the regularly replenished
            (and therefore oxygenated) water. The bronze pump should be installed in a return loop added to the hot water supply plumbing after the
            furthest tap in the circuit. The return tapping should be into the upper third of the hot water storage tank (in order to avoid de-stratifying
            the tank contents).


            • Standard 1 1/2" fittings                      • Pump body material: Bronze, stainless steel, copper
            • Max Head: 6m                                  • Dimensions: H 130mm x W 180mm x D 130mm
            • Low-noise                                     • Joint type: Screw G1
            • Maintenance-free                              • Joint dimensions: 1 1/2"
            • Strong bronze body                            • Frequency: 50Hz. AC power
            • Max Head: 6m                                  • Max system pressure= 1.0Mpa
            • Power: 45w                                    • Certificate: CCC, CE, GS, RoHS, ISO9001: 2000
            • Voltage: 230V                                 • Structure: Single-stage Centrifugal Pump

            Dimensions                                      Applications:
            Height 130mm x Width 180mm x Depth 130mm        Air-conditioning system
                                                            Industrial circulation system
       28                                                                                                        47